Introduction:

Water is the best fluid for heat transfer in industrial systems — cheap, safe, and with a high heat capacity. But even “good” water can be a silent killer if used without chemical planning.

 

Why? Because natural water contains calcium, magnesium, dissolved oxygen, and corrosive ions. These compounds cause two devastating problems:

1. Scale: Hard white layers on hot surfaces → Reduced heat transfer

2. Corrosion:Rust and leaks in pipes and tanks → Safety hazards and high costs

 

In the past, industries resorted to acids — but this method itself caused more severe corrosion. Today, there is a smart and safe solution: an anti-corrosion and anti-scaling solution.


The effect of Mitreh anti-corrosion and anti-scaling solution in protecting industrial equipment

The effect of Mitreh anti-corrosion and anti-scaling solution before and after scale removal

Chemical washing of desalination water / before and after scale removal


Why is Mitreh anti-corrosion and anti-scaling different?

Unlike traditional solutions, Mitreh anti-corrosion and anti-scaling solution is designed based on practical and adaptable chemistry. This product not only prevents scale and corrosion formation, but also improves the performance of the entire system.

 

Mitreh unique features:

✅ Increase the boiling temperature of water (above 100°C) → Suitable for high-temperature systems

✅ Reduce the freezing temperature (below 0°C) → Protection in cold seasons

✅ Prevents foam formation → Smooth and efficient water flow

✅ Creates a nanometer protective layer on the surface of metals

✅ Inhibits scale crystals before they form a layer

✅ Compatible with a variety of metals: steel, copper, aluminum, stainless steel

These features allow your systems to continue to benefit from water, without worrying about damage.


Benefits of using Mitreh Anti-Corrosion and Anti-Scaling Solution

Using this solution is not just a cost — it is a smart investment that will transform your operational efficiency:

  • Increase thermal efficiency by up to 20%
  • Reduce energy consumption (fuel, electricity, water)
  • Increase equipment life by up to 2–3 times
  • Reduce repair and replacement costs
  • Prevent sudden production line stops
  • Comply with environmental and safety standards

 

A few real examples:


Mitreh brand


Key applications of Mitreh in industry

1. Boilers and steam boilers

  • Problem: Scale on hot pipes + corrosion in steam lines
  • Solution: Special formulations based on film-forming amines and stabilized phosphates
  • Result: Increased efficiency, reduced fuel consumption, prevention of thermal explosions

 

2. Chillers and heat exchangers

  • Problem: Insulation of heat exchange surfaces
  • Solution: Anti-scale materials based on phosphonates and inhibitor polymers
  • Result: Reduced electricity consumption, increased cooling capacity

 

3. Cooling towers

  • Problem: Microbial corrosion + scale in open/closed circuits
  • Solution: Special formulations for open circuits (resistant to evaporation) and closed circuits (with anti-freeze and anti-boiling properties)
  • Result: Longer life of fans, pumps and pipes

 

4. Thermal desalination plants (MED/MSF)

  • Problem: Severe scale at high temperatures
  • Solution: Anti-scale materials with thermal stability Top
  • Result: Reduced downtime, increased freshwater production

Application of Mitreh anti-corrosion solution in the oil, gas and petrochemical industries

Protected Water Circulation Systems


How to choose the best type of mitreh?

Not all systems are the same. Therefore, the exact choice of formulation type is based on:

  • Water chemical composition (hardness, pH, TDS, dissolved oxygen)
  • Type of metal in the system
  • Operating temperature and pressure
  • System type (open or closed circuit)
  • Industrial standards (API, ASTM, ISO)

In practice, this choice requires water analysis and expert advice. Abrizan Industrial Research Company, with more than 20 years of experience, determines the exact type of solution, dosage and timing of use using specialized and advanced laboratories.


Specialized services include:

  • Complete water and sediment analysis
  • Corrosion testing with Corrosion Coupons
  • Design of a chemical maintenance program
  • Perform chemical flushing if necessary

Frequently Asked Questions (FAQ)

Does mitreh solution interfere with drinking water?

No. In industrial systems, circulating water is completely separate from drinking water. Also, the formulations are non-toxic and environmentally friendly.

 

 When should Mitreh be used?

From the first day of system commissioning! Prevention is always cheaper and more effective than cure.

 

 Do these solutions clog filters?

No. Mitreh formulations are designed to not cause any secondary deposits.

 

 Are they also suitable for domestic systems?

Yes, there are also special versions for domestic heating systems.


Conclusion: Chemical intelligence for the future of your industry

Mitreh anti-corrosion and anti-scale solution is not just a chemical product — it is a comprehensive solution for optimizing performance, reducing costs and increasing safety.

If you operate in industry and have systems with circulating water, expert advice and testing can make the difference in the life of your equipment for many years. Today, Abrizan Industrial Research Company, with more than two decades of experience in this field, offers comprehensive services including water analysis, custom formulation design, and chemical cleaning implementation — so you can enjoy the benefits of water with peace of mind, without worrying about corrosion and scale.


What's next?

  • Share this with your technical team
  • Submit a water and scale sample from your system for analysis
  • Implement a comprehensive plan to protect your equipment

Specialized monitoring of industrial systems with Mitreh anti-corrosion solution

Abrizaan technical team monitoring the water circulation system


Mitreh's specialized anti-fouling and anti-corrosion products

The table below lists some of Mitreh's specialized formulations for various industrial applications:

Product code

Chemical base

Main application

Mitreh 962

Phosphonate + stabilized phosphate

Heat exchangers

Mitreh 1148

Polymer compounds

Medium pressure steam boilers

Mitreh 958

Nitrite-Nitrate-Borate

Closed circuit cooling tower

Mitreh 956

Silicates

Closed circuit cooling tower

Mitreh 951

Silicate + Polyphosphate

Closed circuit cooling tower

Mitreh 943

Phosphate + polymers

Open circuit cooling tower

Mitreh 948

Stabilized phosphates

Open circuit cooling tower

Mitreh 1153

Special formulation

Multi-stage desalination plants

Mitreh 1138

Phosphate + polyphosphate

Heat exchangers

Mitreh 1149

Polyphosphate

High pressure steam boilers

Mitreh 764

Film-forming amines

Medium pressure steam boilers

Mitreh 768

Neutralizing compounds

Medium pressure steam boilers

Mitreh 760

Sodium phosphate

Medium pressure steam boilers

Mitreh 971

Neutralizing amines

High pressure steam boilers

Mitreh CS0032

Antifreeze + anti-boil + anti-foam

Closed circuit cooling tower

Mitreh 1066

Polyphosphate

Closed circuit cooling tower

View product categories of Abrizan Industrial Research Company

Each formulation is designed based on precise operating conditions and verified by laboratory tests.

☎️ Contact Abrizan Company Specialists ☎️

author: تیم تولیدمحتوای آبریزان

share :

Submit your opinion

Your email address will not be published.


Related Articles

تاثیر کلرین و کلراید بر فلزات استنلس استيل
05/02/2025

Effect of chlorine ions on stainless steels

The effect of chlorine and chloride parameters on the corrosion of stainless steels and the parameters affecting their corrosion rate, as well as the acceptable limits of chlorine ion levels in water and the differences in the effects of free chlorine and chloride on the corrosion of corrosion-resistant steels, are stated.

خوردگی ناشی از سود کاستیک
12/01/2025

Caustic corrosion

Localized corrosion caused by the concentration of caustic or alkaline salts, which usually occurs under conditions of high evaporation or heat transfer. Caustic salt or caustic soda is one of the most widely used ionic compounds and is used in various industries including water treatment, cardboard and paper production, oil and refinery industries, aluminum production industries, food industries, alcohol production and glass.

خوردگی درون سیستم خنک کننده
08/01/2025

Corrosion and deposition of cooling water based on API 571

It refers to general or localized corrosion of carbon steels and other metals caused by dissolved salts, gases, organic compounds, or microbiological activity.

خوردگی میکروبیولوژیکی
05/01/2025

Microbial corrosion based on API 571

Microbial corrosion is a type of corrosion caused by living organisms such as bacteria, algae, or fungi. This type of corrosion is often associated with tubercles or slimy organic materials.

خوردگی در محیط های مختلف
25/12/2024

Corrosion process in different environments

Corrosion processes are divided into three groups in a more comprehensive classification: corrosion in aqueous solutions or environments, corrosion in molten salts and liquid metals, and corrosion in gases.

بازدارنده خوردگی محلول در نفت
25/12/2024

Oil-soluble corrosion inhibitor for the protection of oil transfer and storage equipment

Corrosion is a natural phenomenon that occurs as a result of the electrochemical reaction of metal with the surrounding environment. In the oil and gas industry, corrosion is one of the major problems that accounts for a huge amount of money annually. Part of these amounts are related to the corrosion of pipes or oil transmission lines. Effective ways to prevent corrosion of oil transmission and storage equipment are divided into two categories: physical and chemical solutions.

کوپن گذاری خوردگی
25/12/2024

couponing

The coupon method or corrosion coupons is the simplest method of corrosion monitoring. Coupons are the oldest corrosion monitoring tool. Corrosion coupons are small pieces of metal or alloy of the material of interest that are immersed in the process medium and removed after a specified period of time and their weight or dimension loss is evaluated and examined.

دی اریتورها
25/12/2024

Deaerators

Deaerators are mechanical devices that remove dissolved gases from the boiler feedwater. By reducing the concentration of oxygen and carbon dioxide in the solution, they minimize corrosion and protect the boiler from the effects of corrosive gases.